Electric Flange Ball Valve
Electric flanged ball valves are quarter-turn (0–90°) rotary valves with electric actuation for on/off control, providing reliable shutoff, low pressure drop, and a compact, low-maintenance design for a wide range of media and services.
Explosion Proof Electric Ball Valve
,Electric Flange Ball Valve Actuator
,Explosion Proof Flange Ball Valve
Electric flanged ball valves are quarter-turn (0–90°) rotary valves driven by electric actuation for on/off control. They deliver reliable shutoff, low pressure drop, and a compact, low-maintenance design suitable for a wide range of media and service conditions.
Exploded View of Electric Long Flange Ball Valve
Dual-seat spherical sealing delivers zero-leakage performance for leak-free media containment.
PTFE seats are self-lubricating and low-friction against the ball, extending service life.
Ball ports are offered in rectangular, V-port, and O-port configurations to match different control requirements.
| Nominal Diameter (DN) | DN15 – DN200 |
| Operating Power Supply | AC110V, AC220V, AC380V, DC24V |
| Medium Temperature | -20°C to 350°C |
| Working Pressure | PN1.0 ~ 10.0MPa |
| Control Method | Modulating or On/Off Control |
| Protection Class | IP67 |
| Connection Type | Flange Type |
| Sealing Type | Elastic Seal, High-Temperature Resistant PPS (Polyphenylene Sulfide), Hard Alloy & Industrial Ceramics |
| Leakage Rate | Complies with ANSI B16.104 Class 5 Standard |
| Body Material | A105, F304, F316, WCB, FZG1Cr18Ni9Ti, ZG1Cr18Ni12Mo2Ti, CF8, CF8M, CF3M |
| Ball Material | SUS304, SUS316 |
| Seat Material | PTFE (Normal Temperature) |
| Design & Manufacturing | GB 12237-2007, API 6D |
| Flange Standards | JB/T 79-2015 |
| Face-to-Face Dimension | GB 12221-2005 |
| Inspection Standard | API 598 |
| Power Supply | AC110V, AC220V, AC380V, DC24V |
| Nominal Diameter | DN15 – DN200 |
| Medium Temperature | -20°C to +350°C (+200°C for special seal) |
| Working Pressure | PN1.0 ~ 10.0MPa |
| Control Mode | Regulation or On-Off Control |
| Connection Type | Flanged |
| Body Material | A105, F304, F316, WCB, FZG1Cr18Ni9Ti, ZG1Cr18Ni12Mo2Ti, CF8, CF8M, CF3M |
| Seat Material | PTFE (normal temperature), Special PPL (high temperature), Metal seal (high temperature) |
| Leakage Class | ANSI B16.104 Class 5 |
| Sealing Type | Elastic seal, High temperature resistant polyphenylene, Hard alloy, Industrial ceramic |
| Applicable Medium | Water, Petroleum, Nitric acid, Acetic acid, Viscous fluid, Slurry, Strong oxidizing medium |
| Protection Grade | IP67 |
| Design and Manufacturing Standard | GB12237-2021, API 6D |
| Flange Standard | JB/T 79-2015, GB/T 9124.1-2019, GB/T 9124.2-2019, ANSI B16.5, JIS B2239 |
| Face-to-Face Dimension | GB12221-2005 |
| Inspection Standard | API 598 |
1. Installation dimensions of electric flange ball valve
2. Installation dimensions of electric flanged ball valve (JIS standard)
Flanged Electric Ball Valve (Long Flange) — National Standard Installation Dimensions. Design Standard: GB/T 12237-2007; Flange Standard: HG/T 20592; Unit: mm
| Nominal Diameter (DN) | in | L | D | K | D1 | n-Φd | b | i | H | W1 | W2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 15 | 1/2″ | 130 | 95 | 65 | 45 | 4-Φ14 | 14 | 2 | 209 | 196 | 145 |
| 20 | 3/4″ | 130 | 105 | 75 | 55 | 4-Φ14 | 16 | 2 | 211 | 196 | 145 |
| 25 | 1″ | 142 | 113 | 85 | 65 | 4-Φ14 | 18 | 2 | 218.5 | 196 | 145 |
| 32 | 1 1/4″ | 165 | 140 | 100 | 78 | 4-Φ18 | 18 | 2 | 233 | 196 | 145 |
| 40 | 1 1/2″ | 165 | 150 | 110 | 85 | 4-Φ18 | 18 | 2 | 234 | 196 | 145 |
| 50 | 2″ | 203 | 165 | 125 | 100 | 4-Φ18 | 20 | 2 | 248 | 196 | 145 |
| 65 | 2 1/2″ | 222 | 185 | 145 | 120 | 8-Φ18 | 20 | 2 | 294 | 255 | 182 |
| 80 | 3″ | 241 | 200 | 160 | 135 | 8-Φ18 | 21 | 2 | 320 | 255 | 182 |
| 100 | 4″ | 305 | 220 | 180 | 155 | 8-Φ18 | 22 | 2 | 339 | 255 | 182 |
| 125 | 5″ | 356 | 250 | 210 | 184 | 8-Φ18 | 22 | 3 | 392 | 255 | 182 |
| 150 | 6″ | 394 | 285 | 240 | 210 | 8-Φ23 | 24 | 3 | 402 | 255 | 182 |
| 200 | 8″ | 457 | 340 | 295 | 265 | 12-Φ23 | 26 | 3 | 467 | 255 | 182 |
| Nominal Diameter DN | L | D | K | D1 | b | i | n-Φd | H | W1 | W2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 15 | 108 | 95 | 70 | 51 | 12 | 2 | 4-Φ15 | 209 | 196 | 145 |
| 20 | 117 | 100 | 75 | 56 | 14 | 2 | 4-Φ15 | 213 | 196 | 145 |
| 25 | 127 | 125 | 90 | 67 | 14 | 2 | 4-Φ19 | 221 | 196 | 145 |
| 32 | 140 | 135 | 100 | 76 | 16 | 2 | 4-Φ19 | 229 | 196 | 145 |
| 40 | 165 | 140 | 105 | 81 | 16 | 2 | 4-Φ19 | 239 | 196 | 145 |
| 50 | 178 | 155 | 120 | 96 | 16 | 2 | 4-Φ19 | 246 | 196 | 145 |
| 65 | 190 | 175 | 140 | 116 | 18 | 2 | 4-Φ19 | 306 | 255 | 182 |
| 80 | 203 | 185 | 150 | 126 | 18 | 2 | 8-Φ19 | 316 | 255 | 182 |
| 100 | 229 | 210 | 175 | 151 | 18 | 2 | 8-Φ19 | 339 | 255 | 182 |
| 125 | 356 | 250 | 210 | 182 | 20 | 2 | 8-Φ23 | 371 | 255 | 182 |
| 150 | 394 | 280 | 240 | 212 | 20 | 2 | 8-Φ23 | 399 | 255 | 182 |
| 200 | 457 | 330 | 290 | 262 | 20 | 2 | 12-Φ23 | 438 | 255 | 182 |
Switching Action Mode: Switching operations (open/close) are achieved via AC switching signals, and a set of active position signals indicating fully open / fully closed status are output.
Switching Action Mode: Outputs passive contact signals.
Structure: Equipped with two intermediate position switches.
Switching Action Mode: Outputs 0~1000Ω feedback signal.
Structure: Equipped with 500Ω or 1kΩ potentiometer.
Switching Action Mode: Outputs 4~20mA valve position feedback signal.
Structure: Equipped with 1kΩ potentiometer and R/I converter.
Regulating Action Mode: Accepts 4~20mA control signal input and outputs 4~20mA valve position feedback signal.
Structure: Integrated with 1kΩ potentiometer and control module (servo amplifier).
Switching Action Mode: DC switching signals are output from the circuit via an external DC power supply to control the opening/closing program, and a set of passive contact signals corresponding to fully open / fully closed positions are provided.
Switching Action Mode: Controls valve opening angle via switching circuit, corresponding to potentiometer resistance value, while enabling intermediate position control function.
Structure: Integrated with potentiometer and intermediate position switch.
Switching Action Mode: Three-phase AC switching signals are output through an external three-phase power phase-reversing circuit to control opening/closing operations, accompanied by a set of passive contact signals for fully open / fully closed position indication.
Scan to add on WeChat