Explosion-Proof Electric Ball Valve
,Ultra-Short Ball Valve Actuator
,Explosion-Proof Electric Actuator
The GRAT explosion-proof electric ultra-short ball valve is an automated quarter-turn valve engineered for explosive atmospheres. A stainless steel or WCB body paired with PTFE/PPL seats delivers bubble-tight, corrosion-resistant shutoff, while the explosion-certified electric actuator enables fast quarter-turn or modulating control. It is built for oil & gas, chemical, pharmaceutical, and wastewater service.
Full-Bore Explosion-proof Electric Ball Valve
V-Port Explosion-proof Electric Ball Valve
- Compact, lightweight design for quick, space-saving installation.
- Functions as on/off isolation or modulating control across a wide range of media.
- PTFE/PPL seat inserts provide self-lubricating, low-friction sealing that extends service life.
- Rotating, non-rising stem keeps packing stable; sealing tightens as line pressure rises.
- Blowout-proof, bottom-entry stem with shoulder retention; fire-safe metal-to-metal seal if the seat is compromised.
- Anti-static design: springs between ball, stem, and body dissipate static charges during operation.
- Handles oil, water, gas, slurry, pulp, and fibrous media across chemical, power, metallurgy, and light-industry service.
| Nominal Diameter (DN) | DN15 – DN200 |
|---|---|
| Operating Power Supply | AC110V, AC220V, AC380V, DC24V |
| Medium Temperature | -20°C to 350°C |
| Working Pressure | PN16, PN25, PN40, PN64 |
| Control Method | Modulating or On/Off Control |
| Protection Class | IP67 |
| Connection Type | Flange Type |
|---|---|
| Sealing Type | Elastic Seal, High-Temperature Resistant PPS (Polyphenylene Sulfide) |
| Leakage Rate | Complies with ANSI B16.104 Class 5 Standard |
| Body Material | WCB, SUS304, SUS316 |
|---|---|
| Ball Material | SUS304, SUS316 |
| Seat Material | PTFE (Normal Temperature) |
| Design & Manufacturing | GB 12237-2007, API 6D |
|---|---|
| Flange Standards | JB/T 79-2015 |
| Face-to-Face Dimension | GB 12221-2005 |
| Inspection Standard | API 598 |
| Item | Specification |
|---|---|
| Operating Power Supply | AC110V, AC220V, AC380V, DC24V |
| Nominal Diameter | DN15 – 200 |
| Medium Temperature | -20℃ to +350℃ (+200℃ for special sealing) |
| Working Pressure | PN16, PN25, PN40, PN64 |
| Control Mode | Regulating or On-Off Control |
| Connection Type | Flanged Type |
| Valve Body Material | WCB, SUS304, SUS316 |
| Valve Core Material | SUS304, SUS316 |
| Valve Seat Material | PTFE (normal temperature), Special PPL (high temperature) |
| Leakage Rate | Complies with ANSI B16.104 Class V Standard |
| Sealing Form | Elastic Sealing, High Temperature Resistant Para-Polyphenylene |
| Applicable Medium | Water, Petroleum, Nitric Acid Series, Acetic Acid Series Viscous Fluids, Strong Oxidizing Media, etc. |
| Protection Class | IP67 |
| Design and Manufacturing Standards | GB12237-2021, API 6D |
| Flange Standards | JB/T 79-2015, GB/T 9124.1-2019, GB/T 9124.2-2019, ANSI B16.5, JIS B2239 |
| Structural Length | GB12221-2005 |
| Inspection Standard | API 598 |
Installation dimensions of the explosion-proof electric ball valve.
| Nominal Diameter (DN) | in | d | D1 | K | D | n-Md | f | L | H1 | W1 | W2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| DN15 | 1/2〃 | 15 | 45 | 65 | 95 | 4-M12 | 2 | 43 | 240 | 217 | 150 |
| DN20 | 3/4〃 | 19 | 55 | 75 | 105 | 4-M12 | 2 | 43 | 246 | 217 | 150 |
| DN25 | 1〃 | 25 | 65 | 85 | 115 | 4-M12 | 2 | 50 | 253 | 217 | 150 |
| DN32 | 1-1/4〃 | 28 | 76 | 100 | 140 | 4-M16 | 2 | 50 | 260 | 217 | 150 |
| DN40 | 1-1/2〃 | 38 | 83 | 110 | 148 | 4-M16 | 3 | 67 | 270 | 217 | 150 |
| DN50 | 2〃 | 49 | 102 | 125 | 156 | 4-M16 | 3 | 72 | 279 | 217 | 150 |
| DN65 | 2-1/2〃 | 64 | 120 | 145 | 185 | 4-M16 | 3 | 94 | 325 | 217 | 150 |
| DN80 | 3〃 | 73 | 143 | 160 | 200 | 8-M16 | 3 | 120 | 336 | 268 | 180 |
| DN100 | 4〃 | 90 | 168 | 180 | 220 | 8-M16 | 3 | 141 | 346 | 268 | 180 |
| DN125 | 5〃 | 110 | 185 | 210 | 245 | 8-M16 | 3 | 165 | 421 | 268 | 180 |
| DN150 | 6〃 | 145 | 208 | 240 | 277 | 8-M20 | 3 | 225 | 446 | 268 | 180 |
| DN200 | 8〃 | 195 | 265 | 395 | 335 | 12-M20 | 3 | 275 | 536 | 268 | 180 |
Switching Action Mode: Switching operations (open/close) are achieved via AC switching signals, and a set of active position signals indicating fully open/fully closed status are output.
Switching Action Mode: Outputs passive contact signals. Structure: Equipped with two intermediate position switches.
Switching Action Mode: Outputs 0~1000Ω feedback signal. Structure: Equipped with 500Ω or 1kΩ potentiometer.
Switching Action Mode: Outputs 4~20mA valve position feedback signal. Structure: Equipped with 1kΩ potentiometer and R/I converter.
Regulating Action Mode: Accepts 4~20mA control signal input and outputs 4~20mA valve position feedback signal. Structure: Integrated with 1kΩ potentiometer and control module (servo amplifier).
DC switching signals are output from the circuit via an external DC power supply to control the opening/closing program, and a set of passive contact signals corresponding to fully open/fully closed positions are provided.
Switching Action Mode: Controls valve opening angle via switching circuit, corresponding to potentiometer resistance value, while enabling intermediate position control function. Structure: Integrated with potentiometer and intermediate position switch.
Three-phase AC switching signals are output through an external three-phase power phase-reversing circuit to control opening/closing operations, accompanied by a set of passive contact signals for fully open/fully closed position indication.
Scan to add on WeChat