Quick-Opening Electric Actuator — This quick‑opening actuator is engineered to open and close valves at high speed. It completes the full 0‑90° stroke within 3 to 8 seconds.
This quick‑opening actuator is engineered to open and close valves at high speed. It completes the full 0‑90° stroke within 3 to 8 seconds. Perfect for emergency shut‑off and rapid‑response control tasks, it is built to be highly reliable a
quick-opening electric actuator
,high-speed valve actuator
,explosion proof electric actuator
This quick-opening electric actuator is engineered to open and close valves at high speed, completing the full 0–90° stroke within 3 to 8 seconds. It is ideal for emergency shut-off and rapid-response control tasks, delivering high reliability and an extended service life.
- Low power consumption with high output torque.
- Dustproof and waterproof construction rated IP67.
- Hysteresis < 0.5%, dead zone < 0.5%, and feedback error < 0.5% for precise control.
- Full 0–90° rotation angle, compatible with ball valves and butterfly valves.
- Available control signals: 4–20mA, 0–10V, and Modbus.
- Integrated dehumidification and heating function.
- Passive contact switch and over-torque protection for safe operation.
| Output Torque | 10 N·m | 20 N·m | 50 N·m | 75 N·m | 100 N·m | 200 N·m | 500 N·m |
|---|---|---|---|---|---|---|---|
| Recommended Valve — Ball Valve | DN15 | DN20 | DN25–32 | DN40 | DN50–65 | DN80–100 | DN125–200 |
| Recommended Valve — Butterfly Valve | DN40 | DN50–65 | DN80–100 | DN125 | DN150 | DN200 | DN250–300 |
| Action Time | 3S / 4S / 6S | 3S / 4S / 6S | 4S / 6S | 6S / 8S | 6S / 8S | 6S / 8S | 15S |
| Rotation Angle | 0–90° | 0–90° | 0–90° | 0–90° | 0–90° | 0–90° | 0–90° |
| Motor Power — AC220V | 10W | 25W | 40W | 90W | 90W | 120W | 140W |
| Motor Power — AC380V | 6W | 15W | 30W | 40W | 40W | 90W | 120W |
| Motor Power — DC24V | 13W | 25W | 35W | 70W | 70W | — | — |
| Rated Current — AC220V | 0.16A | 0.32A | 0.35A | 0.54A | 0.64A | 0.96A | 1.03A |
| Rated Current — AC380V | 0.07A | 0.10A | 0.15A | 0.29A | 0.29A | 0.45A | — |
| Rated Current — DC24V | 1.28A | 2.03A | 3.57A | 5.13A | 3.04A | — | — |
| Weight | 2.5kg | 3.5kg | 8kg | 8.5kg | 9kg | 20kg | 22kg |
| Power Supply | AC 110V, AC 220V, AC 380V, DC 24V, DC 220V (selectable) |
| Accuracy | Backlash ≤ 0.5%, Dead Zone ≤ 0.5%, Feedback Error ≤ 0.5% |
| Insulation Resistance | 100 MΩ at 500 V DC |
| Withstand Voltage | 1,500 V AC for 1 minute |
| Protection Rating | IP67 |
| Limit Components | Electric operation: full open/close limit switches; Manual operation: mechanical stops |
| Protection Device | Overheat protector (auto-resetting type) |
| Installation Orientation | 360° adjustable |
| Electrical Interface | M20×1.5 waterproof cable glands ×2 (1 for power cable, 1 for signal cable) |
| Ambient Temperature | Standard: -30℃ to 60℃; High-temperature type: -50℃ to 125℃ |
| Testing Standard | JB/T8219-2016 |
Switching action mode: open/close operations are achieved via AC switching signals, and a set of active position signals indicating fully open / fully closed status is output.
Switching action mode: outputs passive contact signals. Structure: equipped with two intermediate position switches.
Switching action mode: outputs 0–1000Ω feedback signal. Structure: equipped with 500Ω or 1kΩ potentiometer.
Switching action mode: outputs 4–20mA valve position feedback signal. Structure: equipped with 1kΩ potentiometer and R/I converter.
Regulating action mode: accepts 4–20mA control signal input and outputs 4–20mA valve position feedback signal. Structure: integrated with 1kΩ potentiometer and control module (servo amplifier).
DC switching signals are output from the circuit via an external DC power supply to control the opening/closing program, and a set of passive contact signals corresponding to fully open / fully closed positions is provided.
Switching action mode: controls valve opening angle via switching circuit, corresponding to potentiometer resistance value, while enabling intermediate position control function. Structure: integrated with potentiometer and intermediate position switch.
Three-phase AC switching signals are output through an external three-phase power phase-reversing circuit to control opening/closing operations, accompanied by a set of passive contact signals for fully open / fully closed position indication.
Scan to add on WeChat